您好,欢迎来到推发网 最新产品

价    格

订货量

  • 2000.00

    ≥1个

刘先生
  • 邮箱已验证
  • 手机已验证
𐃆𐃇𐃈 𐃈𐃉𐃈𐃈 𐃊𐃊𐃇𐃇 𐃉𐃋𐃈𐃌𐃈𐃆𐃍𐃉𐃎𐃉𐃋𐃉
  • 发货地四川 成都
  • 发货期限不限
  • 供货总量11111个
产品推荐
供应Teledyne Class A-5
美国Teledyne 氧气传感器选型表

RANGE
BACKGROUND GAS
TELEDYNE INSTRUMENTS
SENSOR OPTIONS
Trace Less than 1000 ppm CO2 in the background gas 311, 316, 317, 318, 3160 B-2C
3000T series L-2C
More than 1000 ppm up to *** CO2 in the background gas All trace oxygen instruments A-2C
Note: To use the A-2C or B-2C sensor in a 3000T series instrument, adapter part number B66378 is required.
Note: The L-2C sensor cannot be used in our older analog models (300 series).
Percent Less than 1000 ppm CO2 in the background gas 311P, 320A / P / BRC, 326, 327, 328 B-1, B-3 standard;
C-3 for high concentration of O2
More than 1000 ppm up to *** CO2 in the background gas A-5


Selecting a Teledyne Oxygen Sensor - Detail

CLASS
(click for spec control drwg.)
PART No. APPLICATION COMMENTS
A-1
oxygen sensor
C6689-A1 Ultra-fast response (90% in less than 4 seconds) in the percent oxygen region. Use only when B-1 response time is insufficient.
A-2C
oxygen sensor
C6689-A2C Used for trace O2 measurements in CO2 containing backgrounds (0.1-*** CO2). CO2 must be present. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
A-2CXL
oxygen sensor
B74033-A2CXL Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
        A-2Cl: Obsolete, use A-2C
        A-3: Obsolete, use A-5
A-5
oxygen sensor
C6689-A5 Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-*** CO2. 90% response is time is 45 seconds. Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration.
B-1
oxygen sensor
C6689-B1 General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas.
B-2C
oxygen sensor
C6689-B2C General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.
INSTA TRACE
oxygen sensor
B71875 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. Used for trace O2 analysis in inert gas and hydrocarbon streams.
B-2CXL
oxygen sensor
C6689-B2CXL Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.
B-3
oxygen sensor
C6689-B3 Percent O2 analysis, best compromise between long life and fast response. May be used to spot check flue gas.
B-4C
oxygen sensor
C14613-B4C Trace O2 cell specifically designed for the Model 317EXI. Same performance as the B-2.
B-5
oxygen sensor
C45091-B5 Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3. Requires 3x the amplifier gain of the B-3. Expected life is 36 months in air.
B-5F
oxygen sensor
C45091-B5F Special application cell (non-standard) where long life and moderately fast response, in the presence of CO2, are required. Uses Type F (acid electrolyte). Requires higher amplifier gain than normal. 90% response time is 13 seconds. Expected life in air is 6 months.
B-7
oxygen sensor
C45091-B7 Special application cell (non-standard) where fast response is required; the B-7 has a factor of 3x the life of a B-1 cell. Requires 3x the amplifier gain of the B-1. Expected life in air is 24 months.
B-7F
oxygen sensor
C45091-B7F Special application cell (non-standard) where moderate life and fast response, in the presence of CO2, are required. Requires higher amplifier gain than normal. 90% response time is 7 seconds. Expected life in air is 3 months.
C-1
oxygen sensor
C6689-C1 Rarely used. Schematic for reference only.
C-2
oxygen sensor
C6689-C2 Rarely used. Schematic for reference only.
C-3
oxygen sensor
C6689-C3 Percent O2 measurements where maximum cell life is desired (high O2 applications). 90% response time is 30 seconds. Expected life in air is 18 months.
C-5
oxygen sensor
C45091-C5 Special application cell (non-standard) where long life is required; the C-5 has a factor of 3x the life of a C-3 cell. Requires 3x the amplifier gain of the C-3. Expected life in air is 54 months.
C-5F
oxygen sensor
C45091-C5F Special application cell (non-standard) where long life, in the presence of CO2, is required. Requires higher amplifier gain than normal. 90% response time is 30 seconds. Expected life in air is 9 months.
C-6
oxygen sensor
C54090-C6 Motion insensitive percent O2 measurements for use in hand held portable monitors. Best cell for OEM safety applications.
E-1
oxygen sensor
C14991-E1 Special cell with performance characteristic of the C-3 with 5x the life. Cell is 2 to 3 times the length of standard MFCs; requires special mounting. Designed for medical oxygen concentrators.
E-2
oxygen sensor
C57283-E2 Long life cell for use is the Model 3290 (for use in unattended air liquefaction nitrogen skids). Has a 3 to 4 years expected life in air. Minimum range 0-1000 ppm.
F-1R C40371-F1R 0-1000 ppm CO in Air Used in Max 5 and 9950 Portable Combustion Analyzers
F-3 C55194-F3 Rarely used. Schematic for reference only.
INSTA TRACE - CO2 B73016 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Used for trace O2 measurements in CO2 containing backgrounds (0-*** CO2) in the 3000T analyzer series. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. The INSTA TRACE Micro-fuel Cell oxygen sensor is capable of measuring below 1 ppm of oxygen within 15 minutes of installation.
INSTA TRACE - XL
oxygen sensor
B73592 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Specially qualified sensor to operate in XL model analyzers with a low range limit of 0-1 ppm. Used for trace O2 analysis in inert gas and hydrocarbon streams.
K-1
oxygen sensor
C43832-K1 Smallest Micro-fuel Cell, for use in applications where small size or multiple sensing requirements exist. OEM applications; PC board mountable.
        K-2: Obsolete
L-2C
oxygen sensor
C6689-L2C Used for general purpose trace oxygen analysis in the 3000T analyzer series. Has a 2 year expected life.
L-2CI
oxygen sensor
C6689-L2CI Used in the Model 3000T series for trace O2 measurements; use only in CO2 and H2 background mixtures (e.g. inert gas generators). CO2 concentration should be within 20% about some nominal concentration.
S-2C
oxygen sensor
C6689-S2C Trace oxygen cell for use in TurbO2 analyzer. Provides rapid recovery from air calibration (approximately 20 minutes). Low range limit is 0-100 ppm. Has three pin contact system.
Z-2C
oxygen sensor
C6689-Z2C Has the same features as the S-2, except configured for use in the Model 3190. Low range limit is 0-100 ppm. Has normal Micro-fuel Cell contact plate.


Storage Recommendations for Micro-Fuel Cells

After the Micro-fuel Cell barrier bag is sealed, the sensor (cell) continues to react with the oxygen inside the bag.

Eventually, all of the oxygen is consumed and the cell remains in an inert oxygen-free atmosphere until the bag is opened.

The barrier bag transmits negligible amounts of oxygen and other gases, and almost no moisture. Thus the cell can be stored for periods up to 6 months and still provide 90% or better of its expected life when finally placed into use.

Loss of sensor life in storage can be minimized by following a number of practical stocking procedures.


1) Never remove the cell from the barrier bag until the cell is ready to be used.

2) Store the sealed cell in a cool storage chamber. Storage temperature can be room temperature or below. A range of 10 to 22 Celsius is satisfactory.

3) Avoid any prolonged storage in warm or dry environments. Do not store the cells in an area that is exposed to direct sunlight.

4) Maintain careful records of the serial numbers for cells put into stock and for those supplied out of stock. Cells should be supplied from stock on a first-in, first-out basis.

5) Schedule stock cell orders to coincide with the expected need and thereby minimize cell storage periods. Although it is possible to store the cells for reasonably long periods and still maintain cell life, it is advisable to exercise strict discipline in this matter. For instance, set a stock period target of three months. By setting a goal to turn over stock every three months, cell life will be maximized and warranty issues minimized.

供应商信息
公司图片
成都聚飞科技有限责任公司 进入首页

成都聚飞科技有限责任公司,是一家集产品研发、生产、销售和技术服务于一体的高科技公司。主要从事阻旋式料位开关、音叉式料位开关、射频电容式料位开关、射频导纳料位开关、射频导纳料位计、震动棒式料位开关;信号隔离器、信号调理器,隔离配电器;称重显示仪表、称重配料仪表、称重变送器、称重传感器等仪表。产品广泛应用于电力、环保、冶金、化工、建材、食品、石化、橡塑、水处理等领域。 同时公司也代理美国TELEDYNE气体分析仪传感器,美国AII气体分析仪传感器,美国AMI气体分析仪传感器,英国SYSTECH氧分析传感器   公司秉承"质量、信誉"的宗旨,不断地追求产品的高性能、高质量,对用户提供更加优质的个性化服务。在以诚以实待人,互惠互利的基础上,在生意中交朋友,在朋友中做生意,以优质的产品,合理的价格及良好的售后服务,赢得了众多的朋友称赞,友好而富有成效的合作,为彼此的发展创造了机遇,是您理想的合作伙伴。

点击查看>
企业类型 有限责任公司(自然人投资或控股) 注册资本 100.00万人民币
公司注册地址 成都市青羊区中西顺城街69号 统一社会信用代码 915101057978385395
登记机关 青羊区市场监督管理局 法定代表人 刘勋
公司成立日期 2007-03-16 营业期限 2007-03-16至3999-01-01
经营范围 计算机系统服务;软件开发;销售:计算机软件及辅助设备、通讯设备(不含无线电发射设备)、仪器仪表、五金产品、建材、服装、日用杂货、文化体育用品、矿产品、化工产品(不含危险品)、机械设备。(依法须经批准的项目,经相关部门批准后方可展开经营活动)。
联系方式
联系人
刘先生微信
𐃆𐃇𐃈 𐃈𐃉𐃈𐃈 𐃊𐃊𐃇𐃇
成都聚飞科技有限责任公司
  • 电       话 𐃉𐃋𐃈𐃌𐃈𐃆𐃍𐃉𐃎𐃉𐃋𐃉
  • 地       址 四川 成都 锦江区 翠柳湾支路199号凯丽香江4栋3单元705室
  • 免责声明 :

    本页面所展现的供应Teledyne Class A-5信息及其他相关推荐信息,均来源于其对应的商铺,信息的真实性、准确性和合法性由该信息的来源商铺所属企业完全负责。推发网对此不承担任何保证责任。

  • 友情提醒 :

    建议您在购买相关产品前务必确认供应商资质及产品质量,过低的价格有可能是虚假信息,请谨慎对待,谨防欺诈行为。

成都聚飞科技有限责任公司
  • 身份验证
    • 营业执照已上传
    • 邮箱已验证
    • 手机已验证
  • 经营模式
    生产加工
  • 注册资本
    100.00万人民币
  • 企业类型
    有限责任公司(自然人投资或控股)
  • 主营产品
  • 公司地址
    四川 成都 锦江区 翠柳湾支路199号凯丽香江4栋3单元705室
在线留言
本页信息为成都聚飞科技有限责任公司为您提供的"供应Teledyne Class A-5"产品信息,如您想了解更多关于"供应Teledyne Class A-5"价格、型号、厂家请联系厂家,或给厂家留言。 进入店铺 在线留言