The DNFTs come in three models to switch voltages up to 240 VDC:
LED model
LCC model
PRG model
产品选型资料下载:
· DNFT-PRG
· DNFT-LCC
· DNFT-LED
· DNFT-LED-PS
· DNFT-PRG-PS (Programmable)
· DNFT-PRG (Standard, Programmable)
DNFT-PRG-PS (Programmable w/ PS Option)
DNFT-LCC 45 Second Alarm
DNFT-LCC 2 Minute Alarm
DNFT-LCC 3 Minute Alarm
DNFT-LCC 4 Minute 15 Second Alarm
DNFT-LED
DNFT-LED-PS
Digital No-Flow Timer (DNFT)
Premier Digital No-Flow Timer (DNFT)无油流开关产品介绍:
Monitors Movement of Divider Valve Piston 监测分配器柱塞的运动
Closed Loop or Open Loop Operation 开式或闭式回路 Installs Directly to Divider Valve 直接安装在分配器上面
Not Affected By Temperature or Viscosity 不受温度和粘度的影响
Requires No External Power 不需要外接电源
LED or LCC Cycle Indicator 带LED或LCC循环指示
Dependable “Timed” Shutdown Protection 可靠的停机保护
Explosion Proof Rated for 防爆等级:
Class 1, Division 1, Groups A,B,C,D CSA Approved 通过CSA防爆认证 CE Approved 和CE防爆认证
SPECIFICATIONS :
Material..................................................Stainless Steel, Aluminum
Temperature Range............................................. -40 F to +185 F
Switch Rating..........................................................2.5VA/240 VDC
Epoxy Encapsulated............................UL LISTED EL-CAST VFR 641
Alarm/Shutdown......................... Factory default for 2 minute alarm
Power.......................................Field Replaceable -Lithium Battery
Battery....................................................................... P/N 000505
Alternate Battery..........................................Radio Shack 960-0418
Divider Block Application...............Dropsa/Lincoln/SBCO/Lubriquip
Warranty...........................................................................2.5 Years
WHITLOCK DIGITAL NO-FLOW TIMER
506LIT LED-WI-1
DNFT
WHITLOCK INSTRUMENT
07.11.01
1300 N. Texas Odessa, TX 79761
R
915.3373412 Fax 915.335.5926
DIGITAL NO-FLOW TIMER
1.800.337.3412 INSTRUMENT
U.S. PAT. NO. 5,835,372 WHITLOCK
ODESSA, TX USA
DNFT-LED
P/N: 000506
MODEL Factory Sealed RATED 2.5VA / 240VDC
R
II 2G EEx m IIB T5 CE SERIAL #
C US ClI;Zone1;ExmdIICT4 000506
ClI;Div1;Grps.A,B,C,D;T4 ALARM 2-MIN
186200 0344 P/N
KEMA 00ATEX1090 X Amb. -40° C...+85°C
RED-Open Loop ORANGE-Closed Loop GRN-Ground
DNFT-LED
MONITORS MOVEMENT OF DIVIDER
VALVE PISTON FOR DEPENDABLE
"TIMED" SHUTDOWN PROTECTION
CLOSED LOOP OR OPEN LOOP OPERATION INSTALLS DIRECTLY TO DIVIDER VALVE
NOT AFFECTED BY TEMPERATUREOR OIL VISCOSITY
REQUIRES NO EXTERNAL POWER
LED INDICATOR -CYCLE INDICATION
DEDICATED SWITCH CLOSURE TO MONITOR EACH DIVIDER VALVE CYCLE (PS OPTION)
FIELD REPLACEABLE BATTERY
186200 Cl I; Div 1; Grps. A,B,C,D;T4
KEMA 00ATEX1090
X Amb.
-40° C...+85°C
DESCRIPTION
The DNFT-LED is a totally enclosed electronic device, combining the latest technology in microprocessor and transistor components for detecting Slow-Flow and No-Flow of divider block lubrication systems. The DNFT incorporates an oscillating crystal to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability. The magnet assembly and control housing mount directly to the divider valve to become an integral part of the lubrication system. The DNFT operates on a field replaceable lithium battery. If battery voltage drops below normal operating levels, the DNFT goes into alarm mode and the unit cannot be restarted. LED models utilize an LED to indicate each cycle of the divider valve. This enables the operator to easily set and monitor lubrication rates.
OPERATION
Lubricant flow through the divider valve assembly forces the pistons to cycle back and forth causing a lateral movement of a magnet linked to the piston. Movement is monitored by the microprocessor which resets the timer, lights the LED, and allows the unit to continue operation, this indicates one complete cycle of the lubrication system. The microprocessor must receive this cycle in a predetermined time or a shutdown will occur. The DNFT will automatically reset alarm circuit when normal operation of divider valve resumes.
WHITLOCK
506LIT LED-WI-2
DNFT WHITLOCK INSTRUMENT
DIGITAL NO-FLOW TIMER INSTRUMENT P/N 000506 DNFT-TO-LED DIGITAL NO-FLOW TIMER INSTALLS ON DROPSA/LINCOLN/SBCO/LUBRIQUIP DIVIDER
BLOCK. SWITCH RATING 2.5VA 240VDC
1. Loosen all Allen head set screws (A) on DNFT (B) and remove magnet housing (C). Do not remove magnet, spring or spacer from magnet housing.
2. Remove piston enclosure plug (D) from end of divider valve where DNFT will be installed. The DNFT does not have to be installed on the top divider valve. It may be installed on any convenient divider valve, top to bottom. (Notice:Do not install DNFT on Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.)
3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C). Screw magnet housing (C) into end of divider valve (E). Torque to 15 foot pounds max.
4. Slide DNFT (B) all the way onto hex of magnet housing (C). Tighten set screws on hex of magnet housing. Torque 25 inch pounds max.
5. The LED on the DNFT indicates each divider valve cycle. This enables operator to adjust the lubricator pump for correct cycle time and oil consumption recommended by compressor manufacturer. If LED does not blink with compressor running or by manually pumping oil into divider valve, the DNFT must be adjusted. Normal cycle indication is a bright strobe type blink.
6. Before adjusting DNFT, divider valve must be cycling. This can be achieved with the compressor running or by manually pumping oil through the divider valve assembly with a hand priming pump.
7. Adjustment is made by sliding the DNFT (B) all the way on the hex of the magnet housing (C). Tighten set screws on hex of the magnet housing to 25 inch pounds max. Check for LED blink to confirm correct adjustment. If LED does not blink with divider valve cycling, adjust the DNFT back in 1/16" increments. Correct adjustment of the DNFT is confirmed by blinking LED.
8. All conduit and connections should be appropriate for area classification. Notice: Conduit and fittings must be supported to avoid bending magnet housing.
9. After installing magnet assembly and pre-compressor start-up, it is absolutely necessary to purge all air from dividerblock lubrication system. This can easily be accomplished with a lubrication system purge gun.
10.DNFT must be installed with correct magnet assembly for each divider valve manufacturer.
Lincoln-7/16"-20 extended nose with O- ring Dropsa
Trabon-1994 or earlier 7/16"-20 with metal crush gasket SBCO &Trabon-1995 and later 7/16"-20 with O-ring
Notice: When installing more than one DNFT, each DNFT must be wired to a separate alarm circuit of the control panel, annunciator or PLC to simplify troubleshooting the lubrication system and DNFT.
O-RING OR ALLEN HEAD
INTERNALVIEWOF DIVIDERVALVE METAL GASKET (F) DNFT (B) MAGNET HOUSING SPACER SET SCREWS(2) (A) SPRING #22AWG18"LEADS(7)(I)
(E) (C)
WHITLOCK
RED
DIGITALNO-FLOWTIMER
RED GREENINSTRUMENT
GREEN
ORANGE
ORANGE
CYCLEINDICATIONODESSA,TXUSA
MODEL LED
ORANGE
RATED 2.5VA / 240VDC